Offline TOTP implementation with Radiator AAA Server and Windows Server

Recently, we have had multiple customer cases in the need of offline TOTP (time-based one-time password) implementations. Both private enterprises and public institutions working on different fields have discovered an increasing need for offline multi-factor authentication to protect their critical infrastructure. These use cases include for example power companies, transport infrastructure and other use cases that are used in private networks, and where secure authentication is essential at all times.

Many of these customers use Windows Server and Microsoft SQL server in their implementations, so we wanted to share how Radiator AAA Server Software can be used with them when implementing an offline TOTP solution. And as clarified below, given the flexibility of Radiator, other platforms can be used as well⁠—do not hesitate to contact us with your own specific use case in your own infrastructure.

How it is done

We have had a working example in the Radiator goodies directory that can be leveraged to individual needs:

totp.cfg and totp.sql
Sample configuration file for Radiator, showing how to authenticate using TOTP (RFC 6238) one-time-passwords. The sample MySQL database schema provides test users, with and without a PIN.

generate-totp.pl
Supporting script for generating secret values for TOTP and printing them in different text formats and as QR code images.

The existing example is using SQL definitions specific to MySQL and MariaDB database servers. As Radiator is flexible, the same functionality can be achieved on any supported OS and with any database. Here we show how to set up a similar system with Windows Server 2012 to 2022 and Microsoft SQL Server 2012 to 2022, with Radiator AAA Server Software (current version 4.26). The new Windows-specific configuration shown here will also be included in the goodies of the oncoming release of Radiator soon.

To start with, we expect the system with Windows Server is already installed and hardened as needed. Also, installing Microsoft SQL Server and Microsoft SQL Server Management Studio is out of scope of this post. You can try this TOTP setup out also on a standard desktop Windows version and free SQL Server Express (https://www.microsoft.com/en-us/sql-server/sql-server-downloads).

After the prerequisites are met, the next step is to download and install the rest of the needed software packages:

ODBC Driver for SQL Server
https://learn.microsoft.com/en-us/sql/connect/odbc/download-odbc-driver-for-sql-server

Radiator AAA Server Software, Radiator Windows MSI installer
https://radiatorsoftware.com/products/radiator/

After creating a new ODBC data source (be sure to select a 64-bit driver on 64-bit environments), you can test if the DSN is available to Radiator by running a small test script. Start the command shell with correct environment settings by selecting Radiator configuration from the Start menu and then clicking Perl command line. Save and run the following script on the server. The script lists all DSNs it finds, and if you see the newly created DSN, everything is OK.

# List available data sources
#
# Example run:
# C:\> perl list_datasources.pl
# - dbi:ODBC:<datasourcename1>
# - dbi:ODBC:<datasourcename2>

use strict;
use DBI;
my @dsns = DBI->data_sources('ODBC');
foreach my $d (@dsns)
{
  print "- $d\n";
}

If you want to generate TOTP secrets with generate-totp.pl you also need to install the following new modules. The command cpanm makes it easy if you're connected to the internet:

cpanm MIME::Base32
and
cpanm Imager::QRCode

You can also download the modules manually (check for the latest versions), for example:
https://cpan.metacpan.org/authors/id/R/RE/REHSACK/MIME-Base32-1.303.tar.gz
https://cpan.metacpan.org/authors/id/K/KU/KURIHARA/Imager-QRCode-0.035.tar.gz
and install them from local files like:

cpanm MIME-Base32-1.303.tar.gz
cpanm Imager-QRCode-0.035.tar.gz
Create the database and grant the needed privileges to the user (SELECT and UPDATE). Here's the table definition with SQL Server specific field types. The definition is stripped from comments for brevity, and some fields are optional. Please see goodies for full details.
CREATE TABLE totpkeys
(
  id              INT NOT NULL IDENTITY(1,1),
  active          BIT DEFAULT 0,
  created         DATETIME NOT NULL,
  accessed        DATETIME NOT NULL,
  username        VARCHAR(100) UNIQUE NOT NULL,
  tokenId         TEXT,
  pin             TEXT,
  secret          VARCHAR(130) UNIQUE NOT NULL,
  digits          INT DEFAULT 6,
  bad_logins      INT DEFAULT 0,
  last_timestep   INT,
  algorithm       TEXT NOT NULL,
  timestep        INT DEFAULT 30,
  timestep_origin INT DEFAULT 0,
  PRIMARY KEY (id)
);
Insert some example data ( we use 6-digit codes for broader compatibility, and here's only some of the records):
INSERT INTO totpkeys VALUES (1, GETUTCDATE(), GETUTCDATE(), 'mikem', NULL, NULL,
    '3132333435363738393031323334353637383930', 6, 0, NULL, 'SHA1', 30, 0);
INSERT INTO totpkeys VALUES (1, GETUTCDATE(), GETUTCDATE(), 'mikem512', NULL, NULL,
    '31323334353637383930313233343536373839303132333435363738393031323334353637383930313233343536373839303132333435363738393031323334',
    6, 0, NULL, 'SHA512', 30, 0);
INSERT INTO totpkeys VALUES (1, GETUTCDATE(), GETUTCDATE(), 'fred', NULL, 'fred',
    '1111111111111111111111111111111111111111', 6, 0, NULL, 'SHA1', 30, 0);
Then we make modifications to the example TOTP configuration. Change the DBSource name (DSN) and credentials as needed in the <AuthBy SQLTOTP> block. Also, AuthSelect and UpdateQuery are modified with SQL Server syntax:
<AuthBy SQLTOTP>
  DBSource    dbi:ODBC:totp
  DBUsername  totp
  DBAuth      fred

  AuthSelect SELECT secret, active, pin, digits, bad_logins, DATEDIFF(s, '1970-01-01', accessed), \
                    last_timestep, algorithm, timestep, timestep_origin FROM totpkeys WHERE username=?
  AuthSelectParam %0

  UpdateQuery UPDATE totpkeys SET accessed=GETUTCDATE(), bad_logins=?, last_timestep=? WHERE username=?
  UpdateQueryParam %0
  UpdateQueryParam %2
  UpdateQueryParam %1
</AuthBy>
Update the configuration otherwise as needed (ie. make sure paths are correct to your setup, etc.), and set Trace 4 to see the interesting information during testing. (Re)start the Radiator server process to make sure the new configuration will be used, and then you can try your new setup. Importing the keys to your TOTP application can be done with the help of generate-totp.pl script. If you use the predefined examples, you can get the QR codes by running it like
C:\Radiator>perl generate-totp.pl -accountname "mikem" -issuer "Organisation" \
    -algorithm SHA1 -hex_secret "3132333435363738393031323334353637383930" -digits 6 \
    -image_format gif -qrcode_file \temp\mikem.gif

TOTP key to insert into Radiator database: 3132333435363738393031323334353637383930
TOTP key in BASE32 for client: GEZD GNBV GY3T QOJQ GEZD GNBV GY3T QOJQ
Writing QR code file \temp\mikem.gif
otpauth://totp/Radiator:mikem?secret=GEZDGNBVGY3TQOJQGEZDGNBVGY3TQOJQ&issuer=Radiator&
algorithm=SHA1&digits=8&period=30

You can also create new keys by leaving out the -hex_secret parameter and insert the generated hex string into the database.

Then use your preferred method to display the generated QR code image (MS Paint or web browser are fine) and scan the key into your TOTP application. Microsoft and Google have their authenticators available for mobile devices, and Apple's mobile devices have the feature built-in. There's also a free alternative FreeOTP with an open source codebase: https://github.com/freeotp.

After getting your authenticator app set up you're ready for your first TOTP authentication using radpwtst on command line. Replace the password with your time-based response:

perl radpwtst -noacct -user mikem -password 751352
Or if static PIN is used, here PIN "fred" is prefixed to TOTP one-time-password:
perl radpwtst -noacct -user fred -password fred755224

If everything goes as expected you'll see the Access-Accept response on radpwtst's output, and also on the Radiator server's log. And if something fails, the log can be used to pin-point the problem.
This example is just basic password authentication (PAP). You can now change and expand the configuration to enable more elaborate TOTP RADIUS authentication to your devices or software as needed.

Would you like to know more?

If you want to know more how offline TOTP can be implemented for your use case and solution with Radiator, please do not hesitate to contact us. We can always be reached via email at info@radiatorsoftware.com

Tuesday, August 2, 2016

Secure your network and services with Radiator two-factor authentication

Modern services all around the Internet offer different two-factor authentication solutions. They provide stronger security than using only username and password. Two-factor authentication requires a combination of something the user knows and something the user possesses. One common combination is the username and PIN or password with a physical token, such as a specific device, smart card, or mobile phone. The two-factor secured service may range from a web service to a network device to a remote VPN (Virtual Private Network) access – wherever stronger security is needed.

Figure 1: Radiator based two-factor authentication and authorisation architecture

Radiator AAA Server Software provides flexible, interoperable, and scalable two-factor AAA (Authentication, Accounting, and Authorisation) service for any device or service, which can use RADIUS, TACACS, or TACACS+ interface for AAA. The VPN devices can authenticate remote employees, the network devices can authorise administrators, and the web services can identify the users with secure two-factor authentication. All you need is Radiator-based two-factor AAA service and a free mobile phone app, such as Google Authenticator, Microsoft Authenticator, or some other OTP/TOTP/HOTP app. The authenticator app is paired with Radiator two-factor AAA service and particular user credentials, and two-factor authentication are ready to be used.

Another major benefit of using Radiator is its legendary interoperability. Radiator can combine complementary AAA information and functions from Active Directory, LDAP, and even 3rd party two-factor services, such as RSA SecurID, YubiKey, Duo Security, and Vasco Digipass. It can check existence and validity of a user from Active Directory, retrieve a proper VPN group, perform two-factor authentication using TOTP (Time-based One-time Password Algorithm), and then combine the results to a RADIUS authentication and authorisation response, which is sent back to a Cisco ASA VPN device.

Radiator can also extend the functionalities of 3rd party two-factor authentication services by translating and complementing AAA interactions between services and devices. For example, Radiator combines fine-grained TACACS(+)- or RADIUS-based network device configuration authorisation with existing user directories and two-factor authentication. The two-factor authentication data may be retrieved from Radiator itself or some 3rd party service. With the help of Radiator’s extendable two-factor modules, Radiator also supports SMS transfer of one-time-passwords, when using tokens or authenticator app is not feasible.

Radiator and its two-factor authentication functionalities have already been deployed in several different environments such as:
  • Fortune 250 company uses Radiator for two-factor authentication of their global VPN network.
  • IT departments of world’s two top universities provide VPN service for their employees, partners, and students utilising Radiator’s capability to combine Duo Security two-factor authentication service to additional LDAP directory checks.
  • Nordic operator provides multi-function (RSA SecurID, SMS) two-factor authentication service to their enterprise customers.

Would you like to know more?

Contact our team at info@open.com.au to set up a meeting, where we can discuss how Radiator could help you in securing access to your services or network with two-factor authentication.